Model Number |
MH180 |
Hardness tester MH180
l Compact plastic case,suitable for use under poor working conditions. Test at any angle, even upside down.
l Wide measuring range. It can measure the hardness of all metallic materials. Direct display of hardness scales HRB, HRC, HV, HB, HS, HL
l Large screen (segment LCD), showing all functions and parameters. With EL background light.
l Large capacity memory could store 100 groups information.
l Datapro Software to connect with PC via RS232 port. Micro printer support
l Software calibration function.
Configuration:
|
|
No.
|
Item
|
Quantity
|
Remarks
|
|
Standard Configuration
|
1
|
Main unit
|
1
|
|
|
2
|
D type impact device
|
1
|
With cable
|
|
3
|
Standard test block
|
1
|
|
|
4
|
Cleaning brush (I)
|
1
|
|
|
5
|
Small support ring
|
1
|
|
|
6
|
Alkaline battery
|
2
|
AA size
|
|
7
|
Manual
|
1
|
|
|
8
|
Instrument package case
|
1
|
|
|
Optional Configuration
|
9
|
Cleaning brush (II)
|
1
|
For use with G type impact device
|
|
10
|
Other type of impact devices and support rings
|
|
Refer to Table 3 and Table 4 in the appendix.
|
|
11
|
DataPro software
|
1
|
|
|
12
|
Communication cable
|
1
|
|
|
13
|
Micro Printer
|
1
|
|
|
14
|
Print cable
|
1
|
|
Technical Specifications:
l Measuring range:
(170-960)HLD,(17-68.5)HRC,(19-651)HB,(80-976)HV,(30-100)HS,(59-85)HRA,(13-100)HRB
l Measuring direction:360°(↓↖↗↘↙→←↑)
l Hardness Scale:HL、HB、HRB、HRC、HRA、HV、HS
l Display:segment LCD
l Data memory:max. 100 groups(relative to impact times 32~1)
l Working voltage:3V(2 AA size alkaline battery)
l Continuous working period:about 100 hours(With backlight off)
l Communication interface:RS232
Main Application
l Die cavity of molds
l Bearings and other parts
l Failure analysis of pressure vessel, steam generator and other equipment
l Heavy work piece
l The installed machinery and permanently assembled parts.
l Testing surface of a small hollow space
l Material identification in the warehouse of metallic materials
Rapid testing in large range and multi-measuring areas for large-scale work piece
Other type of impact devices
|
Material
|
Method
|
Impact device
|
|
D/DC
|
D+15
|
C
|
G
|
E
|
DL
|
|
Steel and cast steel
|
HRC
|
20~68.5
|
19.3~67.9
|
20.0~69.5
|
|
22.4~70.7
|
20.6~68.2
|
|
HRB
|
38.4~99.6
|
|
|
47.7~99.9
|
|
37.0~99.9
|
|
HRA
|
59.1~85.8
|
|
|
|
61.7~88.0
|
|
|
HB
|
127~651
|
80~638
|
80~683
|
90~646
|
83~663
|
81~646
|
|
HV
|
83~976
|
80~937
|
80~996
|
|
84~1042
|
80~950
|
|
HS
|
32.2~99.5
|
33.3~99.3
|
31.8~102.1
|
|
35.8~102.6
|
30.6~96.8
|
|
Cold work
tool steel
|
HRC
|
20.4~67.1
|
19.8~68.2
|
20.7~68.2
|
|
22.6~70.2
|
|
|
HV
|
80~898
|
80~935
|
100~941
|
|
82~1009
|
|
|
Stainless steel
|
HRB
|
46.5~101.7
|
|
|
|
|
|
|
HB
|
85~655
|
|
|
|
|
|
|
HV
|
85~802
|
|
|
|
|
|
|
Grey cast iron
|
HRC
|
|
|
|
|
|
|
|
HB
|
93~334
|
|
|
92~326
|
|
|
|
HV
|
|
|
|
|
|
|
|
Nodular cast iron
|
HRC
|
|
|
|
|
|
|
|
HB
|
131~387
|
|
|
127~364
|
|
|
|
HV
|
|
|
|
|
|
|
|
Cast aluminium alloys
|
HB
|
19~164
|
|
23~210
|
32~168
|
|
|
|
HRB
|
23.8~84.6
|
|
22.7~85.0
|
23.8~85.5
|
|
|
|
BRASS(copper-zinc alloys)
|
HB
|
40~173
|
|
|
|
|
|
|
HRB
|
13.5~95.3
|
|
|
|
|
|
|
BRONZE(copper-aluminium/tin alloys)
|
HB
|
60~290
|
|
|
|
|
|
|
Wrought copper alloys
|
HB
|
45~315
|
|
|
|
|
|
|
Available type of impact device
|
|
DC: Test hole or hollow cylindrical
|
D+15:
Test groove or reentrant surface
|
C:Test small, light, thin parts and surface of hardened layer
|
G:
Test large, thick, heavy and rough surface steel
|
E: Test super high hardness material
|
DL: Test slender narrow groove or hole
|
Testing conditions:
|
Type of impact device
|
DC(D)/DL
|
D+15
|
C
|
G
|
E
|
|
Impacting energy
Mass of impact body
|
11mJ
5.5g/7.2g
|
11mJ
7.8g
|
2.7mJ
3.0g
|
90mJ
20.0g
|
11mJ
5.5g
|
|
Test tip hardness:
Dia. Test tip:
Material of test tip:
|
1600HV
3mm
Tungsten carbide
|
1600HV
3mm
Tungsten carbide
|
1600HV
3mm
Tungsten carbide
|
1600HV
5mm
Tungsten carbide
|
5000HV
3mm
synthetic diamond
|
|
Impact device diameter:
Impact device length:
Impact device weight:
|
20mm
86(147)/ 75mm 50g
|
20mm
162mm
80g
|
20mm
141mm
75g
|
30mm
254mm
250g
|
20mm
155mm
80g
|
|
Max. hardness of sample
|
940HV
|
940HV
|
1000HV
|
650HB
|
1200HV
|
|
Mean roughness value of sample surface Ra:
|
1.6μm
|
1.6μm
|
0.4μm
|
6.3μm
|
1.6μm
|
|
Min. weight of sample:
Measure directly
Need support firmly
Need coupling tightly
|
>5kg
2~5kg
0.05~2kg
|
>5kg
2~5kg
0.05~2kg
|
>1.5kg
0.5~1.5kg
0.02~0.5kg
|
>15kg
5~15kg
0.5~5kg
|
>5kg
2~5kg
0.05~2kg
|
|
Min. thickness of sample Coupling tightly
Min. layer thickness for surface hardening
|
5mm
≥0.8mm
|
5mm
≥0.8mm
|
1mm
≥0.2mm
|
10mm
≥1.2mm
|
5mm
≥0.8mm
|
|
Size of tip indentation
|
|
Hardness 300HV
|
Indentation diameter
Depth of indentation
|
0.54mm
24μm
|
0.54mm
24μm
|
0.38mm
12μm
|
1.03mm
53μm
|
0.54mm
24μm
|
|
Hardness 600HV
|
Indentation diameter
Depth of indentation
|
0.54mm
17μm
|
0.54mm
17μm
|
0.32mm
8μm
|
0.90mm
41μm
|
0.54mm
17μm
|
|
Hardness 800HV
|
Indentation diameter
Depth of indentation
|
0.35mm
10μm
|
0.35mm
10μm
|
0.35mm
7μm
|
--
--
|
0.35mm
10μm
|
|
No.
|
Type
|
Sketch of non-conventional
Supporting ring
|
Remarks
|
|
1
|
Z10-15
|
|
For testing cylindrical outside surface
R10~R15
|
|
2
|
Z14.5-30
|
For testing cylindrical outside surface R14.5~R30
|
|
3
|
Z25-50
|
For testing cylindrical outside surface
R25~R50
|
|
4
|
HZ11-13
|
|
For testing cylindrical inside surface
R11~R13
|
|
5
|
HZ12.5-17
|
For testing cylindrical inside surface
R12.5~R17
|
|
6
|
HZ16.5-30
|
For testing cylindrical inside surface
R16.5~R30
|
|
7
|
K10-15
|
|
For testing spherical outside surface
SR10~SR15
|
|
8
|
K14.5-30
|
For testing spherical outside surface SR14.5~SR30
|
|
9
|
HK11-13
|
|
For testing spherical inside surface
SR11~SR13
|
|
10
|
HK12.5-17
|
For testing spherical inside surface
SR12.5~SR17
|
|
11
|
HK16.5-30
|
For testing spherical inside surface
SR16.5~SR30
|
|
12
|
UN
|
|
For testing cylindrical outside surface, radius adjustable R10~∞
|
|